Skip to content
Server Security Center
KEVcritical9.8

CVE-2026-111497: Google Brotli Unchecked Return Value

Google Brotli · listed in the CISA catalog of actively exploited vulnerabilities since 2026-10-27.

CVSS v3.1 (Ubuntu)
9.8
critical
EPSS (exploit probability, 30 days)
99.9%
among the highest 0.1% of all CVEs
Added to CISA KEV
2026-10-27
US federal due date 2026-11-10
Ubuntu priority
high

What is CVE-2026-111497?

A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.

CISA required action: Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk guidance and CISA’s “Forensics Triage Requirements”. Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

CISA notes

Upstream versions (CVE record)

From the CVE record published by the vendor or CVE numbering authority.

  • Google Brotli
    Affected
    • ≥ 1.0.3, < 1.0.10
    • ≥ 1.1.0, < 1.1.1
    • ≥ 1.2.0, < 1.2.1
    Fixed in
    • 1.0.10
    • 1.1.1
    • 1.2.1

Also affected (reported by product suppliers)

  • Siemens Desigo CC family V8
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Desigo CC family V9
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Gridscale X DSA
    Affected
    • ≥ V5.3, < V5.4
    Fixed in
    • V5.4
  • Siemens Gridscale X PSS®E
    Affected
    • < V36.8.0
    Fixed in
    • V36.8.0
  • Siemens Integrated PA Suite Tester
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens SENTRON Powermanager V8
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens SENTRON Powermanager V9
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens SICAM PAS CC
    Affected
    • ≥ V6.02
    Fixed in
    not stated
  • Siemens SICAM SCC
    Affected
    • ≥ V7.01
    Fixed in
    not stated
  • Siemens Cloud Connector Configurator
    Affected
    • < V1.24.3
    Fixed in
    • V1.24.3
  • Siemens Common Configurator (CC on IEM)
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Common Configurator on Device (CC on Edge)
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Data Flow Monitoring
    Affected
    • < V3.0.18
    Fixed in
    • V3.0.18
  • Siemens Databus Configurator
    Affected
    • < V4.0.1
    Fixed in
    • V4.0.1
  • Siemens DataXess Configurator
    Affected
    • < V1.5.7
    Fixed in
    • V1.5.7
  • Siemens Edge OPC UA Server Configurator
    Affected
    • < V2.3.10
    Fixed in
    • V2.3.10
  • Siemens Flow Creator Configurator
    Affected
    • < V1.15.1
    Fixed in
    • V1.15.1
  • Siemens Industrial Edge Hub
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Industrial Edge Management Cloud
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens HyperLynx
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Innexis Architecture Native Acceleration 2026
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Insights Hub
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Opcenter Connect Electronics
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Opcenter Connect MOM
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Opcenter Execution Core
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Opcenter Execution Discrete
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Opcenter Execution Foundation
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Opcenter Execution Pharma
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Opcenter Execution Process
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Opcenter Intelligence
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Opcenter Intra Plant Logistics
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Opcenter Quality
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Opcenter RDnL
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Opcenter X
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens PADS Pro Essentials
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens PADS Pro Student Edition
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens PADS Professional
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens PAVE360 Automotive 2026
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Process Preparation X
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Simcenter Executable Digital Twin
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Simcenter Studio
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Teamcenter V2412
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Teamcenter V2506
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Teamcenter V2512
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Teamcenter V2606
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Xpedition Designer
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Xpedition Enterprise
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens COMOS Walkinside
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens Project Server Web Administration Tool
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens SIMATIC BRAUMAT
    Affected
    • ≥ V8.2 Update 1, < V8.2 Update 5
    Fixed in
    • V8.2 Update 5
  • Siemens SIMATIC Profiling Tool
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens SIMATIC SISTAR
    Affected
    • ≥ V8.2 Update 1, < V8.2 Update 5
    Fixed in
    • V8.2 Update 5
  • Siemens SIMATIC WinCC Companion
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens SIMATIC WinCC OA V3.20
    Affected
    • < V3.20.17.1
    Fixed in
    • V3.20.17.1
  • Siemens SIMATIC WinCC OA V3.21
    Affected
    • < V3.21.7
    Fixed in
    • V3.21.7
  • Siemens SIMATIC WinCC Runtime Professional
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens SIMATIC WinCC Unified for Industrial Edge
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens SIMATIC WinCC Unified PC Runtime
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens SIMATIC WinCC Unified SIQENCE
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens SIMATIC WinCC V7/V8
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens TIA Administrator
    Affected
    • all versions
    Fixed in
    not stated
  • Siemens User Management Component (UMC)
    Affected
    • < V2.15.4.1
    Fixed in
    • V2.15.4.1

Ubuntu and Debian releases

A server is vulnerable if it has a package built from the listed source package installed in a version lower than the fixed version for its release.

Check and fix on a server

Run on each Ubuntu or Debian server. Replace brotli with the source package from the table above (this CVE affects 9 source packages).

1. Show installed packages built from the source package, with their versions

dpkg-query -W -f='${binary:Package} ${Version} ${source:Package}\n' | awk '$3=="brotli"'

2. Compare each installed version with the fixed version for your release from the table

I=INSTALLED_VERSION; F=FIXED_VERSION   # replace both
dpkg --compare-versions "$I" lt "$F"; case $? in 0) echo vulnerable ;; 1) echo "fixed or newer" ;; *) echo "check the versions" ;; esac

3. Install the fix

sudo apt update && sudo apt install --only-upgrade $(dpkg-query -W -f='${binary:Package} ${source:Package}\n' | awk '$2=="brotli"{print $1}')

Services keep running the old code until they are restarted – restart the affected service or check with needrestart.

Rows marked “fix via Ubuntu Pro”: these fixes are only installable with an Ubuntu Pro subscription (ESM). Attach the machine first (sudo pro attach, then sudo pro enable esm-infra esm-apps), then run the commands above.

CISA's assessment (SSVC)

Exploitation
Exploited in the wild
Automatable
No – each attack needs manual steps
Technical impact
Total – full control of the component or total information disclosure

Weakness: CWE-787 Out-of-bounds Write, CWE-252 Unchecked Return Value

References

Data: CISA Known Exploited Vulnerabilities (public domain) · CVE Program records incl. CISA ADP enrichment · OSV.dev (CC BY 4.0) incl. Ubuntu and Debian security data · FIRST EPSS · endoflife.date. Updated automatically – facts last changed 2026-11-21. Always confirm with the vendor's or distribution's advisory before patching.